Probes Available with the MGX and MGX II
Loggers

Specifications:
|
|
2PEA-100
Normal Resistivity
8/16/32/64"
|
2SP A,B-1000
Temperature/Fluid Resistivity
|
2PCA-1000
Three-Arm Caliper
|
2PIA-1000
Electromagnetic Conductivity
|
|
Length:
|
111.0cm
(43.7")
|
38cm
(14.9")
|
159cm
(62.6")
|
158cm
(62.2")
|
|
Diameter:
|
39mm
(1.5")
|
39mm
(1.5")
|
39mm
(1.5")
|
39mm
(1.5")
|
|
Weight:
|
4.3kg
(9.5 lbs)
|
1.4kg
(3.1 lbs)
|
7.3
kg (16 lbs)
|
2.7kg
(6 lbs)
|
|
Pressure
Rating:
|
13,790
kPa (2000 PSI) le
|
13,790
kPa (2000PSI)
|
13,790
kPa (2000PSI)
|
10,500
kPa (1500 PSI, optional high-pressure housing to 3000 PSI)
|
|
Operating
Temperature
|
0 to
70°C (32 -158°F)
|
-20
to 80°C (6-176°F)
|
-20
to 80°C (6-176°F)
|
-20
to 50°C (-4 to 122°F)
|
|
Sensor
(detector):
|
stainless
steel electrodes with digital measuring circuitry
|
7-electrode
mirrored Wenner array-FR,
fast response semiconductor-T
|
Microprocessor-controlled
potentiometer
|
Magnetic-induced
electric field coild @ 25 & 50 cm
|
|
Measurement
range:
|
High
Current: 0-250 Wm
Low Current: 0-2500 Wm
|
Fluid resistivity: 0 to 100 Wm
Temperature:-20 to +80°C
Temperature:-20 to +80°C
|
57
to 736mm(2.25 to 29") 39mm with extensions
|
0-10,000 mS/M
|
|
Accuracy:
|
±
1% of full scale
|
Better
than 1% both sensors
|
0.5mm
(0.2")
|
5%
of full scale
|
|
Resolution:
|
0.02%
of full scale
|
FR:0.05%;
Temp:0.01°C
|
0.08mm
(0.003")
|
0.02%
of full scale
|
|
|
2PFA-1000
Temperature/Fluid Resistivity
|
2DVA-1000
Borehole deviation (inclination, bearing, true vertical depth)
|
2SAA-1000
Full Waveform Sonic
|
2PGA-1000
Gamma/SP/Single Point Resistance
|
|
Length:
|
52cm
(20.56")
|
119cm
(47")
|
218cm
(86") standard probe
|
79.5cm
(31.3")
|
|
Diameter:
|
39mm
(1.5")
|
39mm
(1.5")
|
39mm
(1.5")
|
41mm
(1.63") with neoprene skin
|
|
Pressure
rating:
|
13,790
kPa (2000 PSI)
|
20,685
kPa (3000 PSI)
|
20,685
kPa (3000 PSI)
|
13,790
kPa (2000 PSI)
|
|
Operating
Temp:
|
-20
to 80°C (6-176°F)
|
0 to
70°C (32 -158°F)
|
-20
to 70°C (6-158°F)
|
10
to 70°C (14 to 120°F)
|
|
Sensor
(detector):
|
7-electrode
mirrored Wenner array-FR,
fast response semiconductor-T
|
Microprocessor
corrected 3-axis magnetometer/ 3-axis accelerometer
|
Monopole-dipole
configurable wide-band transducer @ 2-30 kHz
|
Nal(tl)
22.2 mm dia. x 76.2 mm long (0.875" x 3")
|
|
Measurement
range:
|
Fluid resistivity: 0-100 Wm
Temperature: -20 to 80°C
|
0 to
360° inclination, 0 to 90° bearing
|
Dynamic
Range: 12 bits + 4 bit gain
|
0-100k
CPS gamma / ± 1500 mV SP, / -5000 W
SPR
|
|
Accuracy:
|
Better
than 1% both sensors
|
±
0.5% inclination
± 1% azimuth
|
1%
|
±
1% of full scale
|
|
Resolution:
|
FR:
0.05%
Temp: 0.01°C
|
±
0.5%
|
less
than 1 µSec/ft
|
0.02%
of full scale
|
|
|
2GHA-1000
Triple Gamma
|
2NUA-1000
Neutron Thermal Neutron
|
HFP-2293
Heat-Pulse Flow Meter
|
KLP-2780
4-pi Omni-Directional Density
|
|
Length:
|
160cm
(64.7")
|
116.8cm
(31.3")
|
122cm (48")
|
142cm (56")
|
|
Diameter:
|
39mm (1.5")
|
39mm (1.5")
|
39mm (1.5"),
50mm with diverter mount
|
nominal 39mm
(1.5")
|
|
Weight:
|
5.0 kg (11 lbs)
|
5.0 kg (11 lbs)
|
5.5 kg (12 lbs)
|
7.4 kg (12 lbs)
|
|
Pressure
rating:
|
20,685 kPa (3000 PSI)
|
20,685 kPa (3000 PSI)
|
20,685 kPa (3000 PSI)
|
20,685 kPa (3000 PSI)
|
|
Operating
Temp:
|
-10 to 70°C (14
to 158°F)
|
-10 to 70°C (14
to 158°F)
|
0 to 70°C (32 to
158°F)
|
0 to 70°C (32 to
158°F)
|
|
Sensor
(detector):
|
2 pairs G-M
tubes+Nal scintillation detector
|
Helium -3,4 Atm.
|
Thermisters, 2cmm
above/below heat grid
|
CS 137
source/scintillation detector
|
|
Measurement
Range:
|
0-100k CPS
|
0-100k CPS
|
0.03-1.0gpm/0.113-3.785 lpm, 0.015-13ft/min/0.046-3.963 m/min.
|
0-100k CPS
|
|
Accuracy:
|
± 5%
|
± 5%
|
± 5%
|
± 1% of full
scale
|
|
Resolution:
|
0.02% of full
scale
|
0.02% of full
scale
|
± 5%
|
0.02% of full
scale
|
|
|
FAC40
Acoustic Televiewer
|
FLP-2492
Spinner (Impeller Flow Meter)
|
|
Length:
|
246cm (96.8")
|
122cm (48")
|
|
Diameter:
|
40mm (1.6")
|
nominal 39mm (1.5")
|
|
Weight:
|
7.4 kg (16.28 lbs)
|
9 kg (19.9 lbs)
|
|
Pressure Rating:
|
16,000 kPa (2320 PSI)
|
13,790 kPa (2000 PSI)
|
|
Operating Temp:
|
0 to 70°C (32-158°F)
|
0 to 70°C (32-158°F)
|
|
Sensor (detector):
|
1.4 MHz, 3x3mm (beamwidth),
user-controlled transducer head; 3-axis magnetometer / accelerometer package
|
4-pulse per revolution
fiber-optic impeller
|
|
Measurement Range:
|
borehole wall features in
boreholes ranging from 46-400mm
|
3 to 102cm/sec (6-200 ft/min)
|
|
Accuracy:
|
1 %
|
1 % of full scale
|
|
Resolution:
|
down to 2mm (fractures to
0.1mm)
|
less than 0.508cm/sec
(<1ft/min)
|
Other Measurements available with the MGX II loggers:
-
Spectral Gamma
-
Water Quality (temperature, pH, Redox, salinity, pressure,
dissolved oxygen, fluid electricalconductivity)
-
Optical Televiewer
(PDF)
-
Dual Focused Induction
-
Fluid Sampler
-
Magnetic Susceptibility
-
Ultra-slim gamma for CPT applications
-
Induced Polarization
Order Information
|
Description
|
|
Order Number
|
|
2PEA-1000
Normal Resistivity
|
|
530-400-0010
|
|
2SF A,G-1000 Temp/Fluid Resistivity
|
|
530-400-0020
|
|
2PCA-1000 Tree-Arm Caliper
|
|
530-400-0030
|
|
2PIA-1000 Electromagnetic Conductivity
|
|
530-400-0040
|
|
2PFA-1000 Temp/Fluid Resistivity
|
|
530-400-0050
|
|
2DVA-1000 Borehole deviation
|
|
530-400-0060
|
|
2PSA-1000 Full Waveform Sonic
|
|
530-400-0070
|
|
2PGA-1000 Gamma/SP/Single point
resistance
|
|
530-400-0080
|
|
2GHA-1000 Triple Gamma
|
|
530-400-0090
|
|
2NUA-1000 Neutron Therman Neutron
|
|
530-400-0100
|
|
HFP-2293 Heat-Pulse Flow Meter
|
|
530-400-0110
|
|
KLP-2780 4-pi Omni-Directional Density
|
|
530-400-0120
|
|
OBI-40 Optical Televiewer
|
|
530-400-0125
|
|
FAC-40
Acoustic Televiewer
|
|
530-400-0130
|
|
FLP-2492 Spinner (impeller) Flow Meter
|
|
530-400-0140
|
|
 |
 |