|

VIP 3000/VIP 4000
IP AND RESISTIVITY ADVANCED TRANSMITTER
Features
General
The VIP family of transmitters is now available in either a
3000 or 4000 watt version. Both VIP Systems are power current regulated Time Domain and
Frequency Domain electrical transmitters.
VIP 3000/VIP 4000 Major Benefits
Light in weight and provided with a high voltage (3000V)
output, the VIP 3000/VIP 4000 are particularly convenient for IP surveys in high
resistivity rugged areas and for deep resistivity soundings.
Microprocessor controlled for ease of operation and
protection against misuse, all injection parameters (current, voltages, ...) are
controlled. The VIP 3000/VIP 4000 can also be operated through its remote control port
(RS232).
The VIP 3000/VIP 4000 eight output dipoles provide for higher
productivity in the field. Powered from a standard 220V single phase motor generator, the
VIP 3000/VIP 4000 eliminate the maintenance and supply problems associated with custom
power sources. It also reduces the costs and problems of shipping motor generators over
long distances, namely by plane.
High Outputs
The VIP 3000/VIP 4000 will generate up to 3000 volts for work
in high resistivity areas and up to 5 amperes at 600 volts (VIP 3000) / 800 volts (VIP
4000) for low resistivity regions.
With its weight of only 16kg, the VIP 3000/VIP 4000 are the
lightest 3000W/4000W units on the market.
Heavy Duty Construction
Very high quality connectors, and heavy duty industrial
components are used throughout. The VIP3000/VIP 4000 are shock resistant and weatherproof,
for a higher reliability.
Fully Automated
The VIP 3000/VIP 4000 are designed for ease of operation.
They have a much simplified front panel: current, dipole and frequency (in the frequency
domain) settings are the only parameters to be selected by the operator. All the other
functions, like voltage range setting, are fully automated.
Programmable
Programming functions are also available, either through the
front panel, with a suitable key, or from an external computer terminal. These functions
are used to select the parameters and options that are not normally changed during a
survey: operating mode, time or frequency domain, cycle time, frequencies, etc.
This approach reduces front panel cluttering and drastically
reduces the possibility of operator mistake. Instrument reliability is also increased. For
example, it is not possible to switch dipoles when transmitting. This eliminates the
possibility of burning out the selector switch or the output circuitry.
Error Messages
Intelligent messages and warnings are displayed in case of
problem or malfunction. Furthermore, the permanent storage of all the parameters related
to the operation of the unit make easier the remote identification of a trouble by the
manufacturer for quicker instrument servicing.
Complete Display
A large backlighted LCD alphanumeric display is provided for
the simultaneous indication of all output parameters. Output current, output voltage,
contact resistance and output power are continuously displayed.
Intelligent Regulation
The VIP 3000/VIP 4000 internal microprocessor is capable of
excellent current regulation in almost any load.
Current is operator selectable in preprogrammed steps from
50mA to 5 amperes. Intelligent current adjustment algorithms are always in operation. For
example, the contact resistance will occasionally be too high for the VIP 3000/VIP 4000 to
provide the requested current setting. In such cases, the VIP 3000/VIP 4000 will display a
warning message and will set the current to the maximum value allowable under that
combination of current setting and contact resistance. Some reserve current capacity will
always be kept to insure that the current stays constant during the measurements, whatever
the contact resistance fluctuations.
Remote Control
The VIP 3000/VIP 4000 are provided with a remote control
port. By using radio modems, it can be operated from a remote location.
The VIP 3000/VIP 4000 can also be linked to an intelligent
receiver such as the ELREC 6 or the ELREC 10, or to a computer, for the automatic
recording of current settings. Finally, synchronization with a receiver or system is also
possible in both directions (i.e. Rx to Tx or Tx to Rx).
Works With Almost Any Power Generator
The VIP 3000/VIP 4000 IP transmitter can be powered by almost
any motor generator providing a nominal 230V, 45-450 Hz output, single phase, at a
suitable KVA rating.
Low cost commercial generator sets, available at local
hardware or equipment rental stores are perfectly suitable.
For related interpretation software see RESIX IP,
RESIX 2DI, and RESIX IP2DI.
Specifications
-
Output Power: 3000/4000VA maximum
-
Output Voltage: 3000 V maximum, automatic voltage range
selection
-
Output Current: 5 amperes maximum, current regulated
-
Current accuracy: better than 1%
-
Current stability: 0.1%
-
Dipoles: 8, selected by push button
-
Output Connectors: connectors accept bare wire or plug of up
to 4mm. diameter.
-
Tune Domain Waveforms: On+, off, on-, off, (on = off)
preprogrammed cycle. Automatic circuit opening in off time. Preprogrammed on times from
0.5 to 8 seconds by factor of two. Other cycles programmable by user.
-
Frequency Domain Waveforms: Square wave, Preprogrammed
frequencies from 0.0625 Hz to 4 Hz by factors of 2. Alternate or simultaneous transmission
of any two frequencies. Other frequencies programmable by user.
-
Time and Frequency Stability: 0.01%, 1 PPB optional
-
Display: Alphanumeric liquid crystal display. Simultaneous
display of output current, output voltage, contact resistance, and output power.
-
Protection: Short circuit at 20 ohms, Open loop at 60000
ohms, Thermal, Input overvoltage and undervoltage.
-
Remote Control: Full duplex RS-232A, 300-19200 bauds. Direct
wire sync for on-time and polarity.
Miscellaneous
-
Dimensions (h w d): 41 x 32 x 24 cm.
-
Weight: 16 kg
-
Power Source: 175 to 270 VAC, 45-450 Hz, single phase Motor
Generator
-
Operating Temperature: -40 to +50 degrees Celsius.
-
Standard Components
-
VIP 3000 or VIP 4000 Console, Programming Key, RS-232
Interface Cable, Motor Generator Cable, Operations Manual and Shipping Case.
Ordering Information
|
Description
|
|
Order Number
|
|
VIP 3000 Transmitter
|
|
500-190-0027
|
|
VIP 4000 Transmitter
|
|
500-190-0028
|
|
Programming Key
|
|
500-190-0029
|
|