ELREC 6
(PDF)
MULTI CHANNEL IP/RESISTIVITY RECEIVER
Features
General
ELREC 6 is a six dipole Time Domain Induced Polarization/Resistivity
Receiver designed for high productivity surveys in mineral and groundwater
exploration
ELREC 6 has been designed for being both a user friendly and very
sensitive IP/Resistivity receiver.
ELREC 6 is available in two models: the first option includes
twenty programmable windows in Time Domain mode, the second provides both ten
programmable windows in Time Domain mode as well as the Frequency Domain mode.
Six dipoles
The six channels of the receiver permit to measure six dipoles
simultaneously, which provides a high efficiency in the field.
Twenty programmable windows
Beside the classical preset logarithmic and arithmetic modes,
ELREC 6 also offers up to twenty fully independent programmable windows which
the operator can define by himself according to the way he wants to sample the
IP decay curve.
Automatic measuring process
A microprocessor fully controls the synchronization, the gain
ranging, the stacking, and the display of the results including the apparent
resistivity.
Monitoring display
During the acquisition, the chargeabilities of the six dipoles
can be displayed simultaneously on the LCD display for a global visualization of
the readings ; the standard deviations of these chargeabilities can also be
displayed simultaneously for a real time monitoring of the quality of the
ongoing readings.
Internal memory
The memory can store up to 2500 readings, each reading including
the full set of parameters characterizing the measurements; the date and time of
the reading, given by the Real Time Clock of the instrument, are also stored. A
serial link permits to transfer the data to a printer or computer.
Remote control
ELREC 6 can be fully driven by a microcomputer through the serial
link for remote operation applications.
Frequency mode
The frequency effect and the phase shift between the fundamental
and the third harmonics may be measured for a Frequency Domain waveform (ON+,
ON-), or for a Time Domain waveform (ON+, OFF, ON-, OFF).
Time Domain waveform (ON+, OFF, ON-, OFF).
Field proof instrument
ELREC 6 operates in a wide range of temperature and humidity. It
also features a fiberglass case for increased resistance to field shocks and
vibrations.
ELREC 6 Measuring Process
Elrec 6 measuring process has been optimized to provide the best
possible accuracy in real field conditions. Included features are:
Available Electrode Arrays A range of electrode arrays are
available, they include Dipole Dipole, Pole Dipole, Pole Pole, Gradient
Rectangle, Schlumberger and Wenner Soundings and Profilings, Borehole
Electrodes, etc.
Noise Monitoring System A monitor function enables the operator
the check the level of noise observed on each dipole before the measurement: the
LCD digital voltmeter function displays the raw instantaneous value of
potential. In reality, it is possible to digitally observe the presence of a
pulse square waveform corresponding to a primary voltage signal and showing the
operation of a transmitter nearby. This function is also available during the
acquisition of a reading.
Line Check/Ground Resistance: A line check/ground resistance
measurement which permits to check that all seven electrodes are properly
connected to the receiver.
Low-Pass Filter: A low-pass analog filter which reduces the
effect of higher frequency natural and cultural noises (50-60 Hz).
Automatic SP Compensation: The automatic SP compensation includes
linear drift correction (up to 1 mV/s) through a digital filter.
Automatic Gain Ranging: automatic gain ranging is applied within
a voltage range of +/- 10V.
Automatic Synchronization Process: ELREC 6 automatically
synchronizes with the signal through a waveform recognition process ; it also
automatically re-synchronizes at each new pulse to avoid errors due to a
possible shift in the period of the transmitted signal.
Automatic Digital Stacking: To enhance the signal-to-noise ratio
for as long as the operator wants, automatic digital stacking stack to a 250
maximum. During the stacking, the operator can monitor either the instantaneous
value (to observe the level of noise), or the cumulative value (to observe the
convergence of the average value).
Continuous Quality Test: A continuous quality test procedure,
which stops the averaging process when the noise level becomes too high, but
keeps the previously stacked data. The averaging procedure starts again when
noise decreases. This procedure optimizes the time of data acquisition in very
noisy areas.
Resolution After Stacking: A resolution after stacking of 1 µV
for primary voltage, and of 0.01 mV/V for chargeability, for pointing out low
amplitude anomalies. The standard deviations of the chargeability of the six
dipoles are displayed during and after the acquisition to give an indication on
the noise level.
Normalized chargeability option : The normalized chargeability
option refers the chargeability to a standard IP decay curve, and permits to
point out any EM coupling effect on the measured signal.
Compatibility: The ELREC 6 is compatible with
VIP 3000 , VIP 4000, VIP10000
and with most of time domain IP/Resistivity Transmitters currently available.
Specifications
-
Input Channels: Six
-
Signal Waveform: Time Domain (ON+, OFF, ON-, OFF) with pulse
duration of 0.5, 1, 2, 4, 8 seconds
-
IP Chargeability Windows: Up to twenty arithmetic, logarithmic,
or fully program- mable
-
Apparent Resistivity Computation: Average chargeability and
standard deviation.
-
Input Impedance: 10 Mohm
-
Input Overvoltage Protection: up to 1000 volts
-
Input Voltage Range: Each dipole: 10V max sum of voltage of
dipoles 2 to 6: 15V max
-
Automatic SP Bucking: ± 10V with linear drift correction up to
1 mV/s
-
Power Line Rejection: 50 to 60 Hz
-
Sampling Rate: 10 ms
-
Common Mode Rejection: 100 dB (for RS = 0)
-
Grounding Resistance: Measurement from 0.1 to 467 Kohm
-
Battery Test: Manual and automatic before each measurement
Primary Voltage:
Chargeability:
-
Resolution : 0.01 mV/V
-
Accuracy: typical 0.6%
-
Memory capacity: 2500 readings
-
Data Transfer: RS 232 link for data transfer to microcomputers
and printers (300 to 19200 baud rate)
-
Remote Control: through the serial link
Frequency Mode
-
Signal waveform: (ON+, ON-) or (ON+, OFF, ON-, OFF)
-
Pulse Duration: 1s or 2s
-
Measured Parameters: Frequency effect and relative phase
fundamental and third harmonics
-
Resolution: about 0.01% after stacking
Miscellaneous
-
Dimensions: 31x21x21 cm
-
Weight: 6 kg with dry cells, 8 kg with internal battery
-
Operating temperature: -40°C to +70°C
-
Power supply: either 12V internal recharge- able battery, or
six 1.5V D size dry cells. In both cases, a 12V external battery can also be
used.
Standard Components
ELREC 6 Console, (Alkaline or Rechargeable Batteries with
Charger), external 12V Power Cable, RS-232 Data Transfer Cable with
Cross-connectors, Data Transfer Program, Operations Manual and Shipping Case.
Ordering Information
|
Description
|
|
Order Number
|
| ELREC 6 w/20 windows |
|
500-200-0010 |
| ELREC 6 w/10 windows & frequency mode |
|
500-200-0015 |
|