PolyElectric Probes2PEA-1000 & 2PEA-1000/FOverview
The function of each electrode is listed below, starting with the bottom electrode and proceeding towards the top of the probe. For more information on the function of these electrodes, consult the Theory of Operation section of this document. Electrodes:
Connectors for the tool are as follows. The PolyGamma probe top described above is a standard single conductor probe top. Other variations of probe tops and wiring can be ordered from the factory. The connector between the PolyElectric and PolyGamma probes is a ring style connector. The numbering of the rings begins from the inner most ring (ring 1) and proceeds to the outer ring (ring 6). PolyElectric BridleThe bridle must be connected between the cable head and the top of the PolyElectric -PolyGamma Probe combination as illustrated. The bridle provides electrical isolation from the logging cable armor for normal resistivity logging. PolyGamma Probe Top Connector:
PolyElectric Probe Top and PolyGamma Probe Bottom Connectors:
The 2PEA-1000/F has fluid temperature and fluid resistivity sensors located on the bottom of the probe. Please call for more information. Theory of OperationNormal Resistivity MeasurementsThe normal resistivity and single point resistance measurements are accomplished by measuring the amount of survey current that the logger and probe produce between the A electrode and the mudplug (or armor during the normal resistivity using armor operational mode). A voltage is measured for each resistance or resistivity channel. All voltage measurements are made with respect to the armor. The quotient between the voltage and current for each channel is used to calculate the reported value. For the normal resistivity measurements, Ohms law can be written
where r is resistivity (ohm-meters), R is resistance (ohms), l is the distance the survey current travels (meters), A is the cross sectional area that the current travels through (meters 2 ), V is voltage (volts), and I is current (amps). The quantity (A/l) is called the geometric factor G (meters). The geometric factor is approximately 12.5 times the AM spacing, in meters. The survey current leaves the A electrode in all directions, diverging as it does so. In a homogenous medium, concentric spheres centered around the A electrode, and with radius AM, delineate the volume of investigation for the normal resistivity measurement. AM refers to the distance between the A and M electrodes. The volume of investigation (in a homogenous medium) for the 8 inch normal resistivity measurement is a sphere with an 8 inch radius; the volume of investigation for the 64 inch normal resistivity measurement is a sphere with a 64 inch radius. These spheres are called equipotential surfaces. The voltage is measured between an equipotential surface (sphere surrounding the volume of investigation) and the reference (armor). This voltage is divided by the measured value of the survey current, and the result multiplied by the geometric factor to obtain resistivity. The normal resistivity circuits report the average resistivity of the material in the volume of investigation and the volume of investigation may vary for heterogeneous mediums. Therefore, the measured resistivity is called the apparent resistivity. Many computer programs are available to convert apparent resistivity to true resistivity. These programs usually require a geologic model and the apparent resistivity data to calculate true resistivity. Some programs calculate synthetic logs such as invasion profile, synthetic focused resistivity logs, and porosity logs. Single Point Resistance MeasurementRefer to Ohms law from above for the explanation of the single point resistance measurement. As the survey current leaves the A electrode, the current diverges, and the cross sectional area A through which it travels becomes very large compared to l. The quantity (l/A) in the first equation approaches zero as the distance from the A electrode increases. Therefore most of the measured resistance is a result of the survey current near the A electrode and also at the mudplug where the current converges. The resistance indicated by the single point resistance circuit, is the sum if the resistance near the mudplug, and the resistance near the A electrode. Since the resistance near the mudplug does not change, any excursion indicated in the single point resistance log is a result of the change in resistance near the A electrode. When the PolyElectric - PolyGamma probe combination is operated in R-SP mode, the current generator and all measure circuits are contained in the logger at the surface. The mudplug is used as the current return (B) and reference (N) electrodes. The top electrode on the probe functions as the current (A) and measure (M) electrodes. In this mode, the top electrode on the probe is connected to the cable line center conductor. Since the probe requires no power, this mode of operation is sometimes referred to as the passive mode. SP measurement The SP (self potential) circuits measure the DC (direct current) voltage between the top electrode on the probe and the armor. The resistivity circuits utilize an AC (alternating current) survey current so that the SP circuits are not affected. When the PolyElectric - PolyGamma probe combination is operated in R-SP mode, the current generator and all measure circuits are contained in the logger at the surface. The mudplug is used as the current return (B) and reference (N) electrodes. The top electrode on the probe functions as the current (A) and measure (M) electrodes. In this mode, the top electrode on the probe is connected to the cable line center conductor. Since the probe requires no power, this mode of operation is sometimes referred to as the passive mode. This mode may give better SP log results near the water level in the borehole. Fluid Resistivity MeasurementThe fluid resistivity measurement generates a survey current between small current (A and B) electrodes located inside the survey tube. Small measure (M and N) electrodes, located between the current electrodes, are used to measure the potential difference generated in the fluid by the current electrodes. The process is identical to that of the normal resistivity measurements, except that the volume of investigation is entirely contained in the survey tube. Fluid Temperature Measurement The fluid temperature measurement uses a solid-state temperature-sensing device. The electrical output of this device is proportional to the temperature of the fluid. The thermal mass of the temperature sensor is kept as low as practical so that the time required for the sensor to respond to a change in temperature is minimal. Derived MeasurementsMeasurements from the PolyElectric probe can be combined to make derived quantities. Lateral resistivity logs and synthetic LL7 logs can be obtained from normal resistivity logs. Mud invasion profiles can be determined with multiple spaced resistivity logs. These profiles illustrate rock permeability. Mud resistivity can be calculated from the fluid resistivity. Mud resistivity can then be used to calculate porosity. Many of these calculated measurements can be made in real time while logging the data. For more information about these and other derived measurements, consult Terraplus. Specifications:
Ordering Information:
|
|
|
|